b'Acurlite Structural Skylights, Inc.16 Installation Manual 17 Prior to installing glass, trim and set all gaskets. Make sure all surfaces receiving glazing and/or silicone are clean and dust free. If structural silicone seals are required silicone Pre-formed cornermust be applied after glass is set.closures"Smoosh" glazing is not an acceptable practice. Reference your shop/erection drawings for glazing locations(not provided by Acurlite if frame only purchase)and project specific glazing details.Seal in and around lug and fastnerApply structural silicone sealant (if required) between glazing and structural seal flange.Apply a generous bead of siliconeSet splice plate over joint.Apply silicone along each edge of on either side of joint.Approxi- splice plate and tool.mately 1-1/2" away from joint.All surfaces receiving silicone should be properly cleaned and primed per sealant manufacturer\'s recommendations. All surfaces receiving silicone should be properly cleaned and primed per sealant manufacturer\'s recommendations.DOWSILproducts or equivalent must be used. Please check with sealant manufacturer for compliance. DOWSIL products or equivalent must be used. Please check with sealant manufacturer for compliance.www.acurlite.com570.759.6882'